V2000-c Rfid Access Control User Manual 2021 Access

Always turn off the main power supply before handling any electrical wiring. Wiring a Fail-Safe Lock (Magnetic Lock) Connect the power supply to the V2000-C +12V .

Enter a number from 0 to 99 (seconds). Note: 0 sets the relay to toggle/latch mode. Press # then * to exit. Access Modes Define how users gain entry to the property. Enter Programming Mode. Press 3 . Select your mode: 0 : Entry by Card Only 1 : Entry by Card OR PIN (Default) 2 : Entry by Card AND PIN combined Press # then * to exit. 5. Troubleshooting and Factory Reset Device is Beeping Continuously Tamper switch triggered or incorrect voltage supply.

Are you looking for a reliable and efficient access control solution for your organization? Look no further than the V2000-C RFID Access Control System. This user manual provides a detailed guide on how to install, configure, and operate the V2000-C system, ensuring that you get the most out of your access control investment.

Card only, Public PIN only, Private PIN only, Card + PIN Current Draw: Active current < 100mA; Idle current < 40mA Relay Output Load: Max 3A

Press * + Master Code + # (Example: * 9 9 9 9 # ) Exit Programming Mode: Press * Changing the Master Code V2000-c Rfid Access Control User Manual

Incorrect wiring is the #1 cause of V2000-c failure. Refer to the pinout diagram (usually on the rear of the device).

For further support, consult your distributor for hardware-level repairs. The V2000-c’s simplicity is its strength – there is no cloud to fail, no subscription fee, and no software to crash. Just security that works.

Turn off the power supply. Press and hold the # key or the exit button loop while restoring power. Hold for 3 to 5 seconds until you hear a series of short beeps. The programming code will revert to the factory default ( 9999 ). User card data will not be erased during this hardware reset.

Below is a based on the standard V2000-C configuration. This summarizes the key capabilities you would find in the user manual, categorized by how they are used. Always turn off the main power supply before

Ensure you are using a 125 kHz EM-frequency card. Mifare 13.56 MHz cards are incompatible with the V2000-C standard reader.

Enter programming mode, then press 0 + [New 6-digit Code] + # + [Repeat New Code] + # . 4. User Management Adding Users (Card or PIN) Enter Programming Mode. Press 1 . For Card: Swipe the RFID card.

Key features of the V2000-C system include:

Connect to positive lock terminal for Fail-Secure locks (Dropbolts/Strikes) NC (Normally Closed) Note: 0 sets the relay to toggle/latch mode

Press 4 ➡️ 2 ➡️ # 7. Troubleshooting and Factory Reset Issue: The keypad does not power up or light up.

Complete Guide and User Manual for the V2000-C RFID Access Control System

A proper wiring configuration prevents premature hardware failure and secures against bypass methods. Ensure the system power supply is completely disconnected before wiring the terminals. Terminal Label Function Description Connection Target 12V Positive DC Input Power Supply Positive (+) GND Ground/Negative Power Supply Negative (-) NC Normally Closed Relay Positive terminal of Fail-Safe Lock (Magnetic Lock) NO Normally Open Relay Positive terminal of Fail-Secure Lock (Electric Strike) COM Common Relay Terminal