Ivoclar — Programat P95 Manual
Maintain at least 25 cm (10 inches) of open space on all sides to allow proper heat dissipation. Do not place items directly on top of the furnace head.
(Vacuum On): The temperature at which the vacuum pump activates. V2cap V sub 2 (Vacuum Off): The temperature at which the vacuum releases. Step-by-Step Firing Guide Follow this sequence for standard daily operations:
Keep a minimum clearance of 25 cm (10 inches) around the unit for ventilation.
Over time, silver from alloys or contaminants from embedding investments can accumulate in the insulation, causing porcelain discoloration. Run an empty "purge" or decontamination cycle at 1000°C with the vacuum engaged for 10 minutes once a week.
The baseline temperature before the firing cycle begins (usually 403°C). Ivoclar Programat P95 Manual
The is a recognized, reliable, fully automatic vacuum ceramic furnace designed specifically for firing dental ceramic materials . Known for its precision and user-friendly design, the P95 combines microprocessor control with a robust heating system to ensure high-quality, consistent results for dental technicians.
Check the rubber ring seal around the lift platform. Tighten hose clamps. Change vacuum pump oil. Broken quartz heating element or failed solid-state relay.
A precise temperature sensor extending into the heating chamber to provide real-time thermal feedback. Installation and Setup Procedures
Clean the lift guide rails with a dry microfiber cloth. Do not apply heavy industrial grease. Maintain at least 25 cm (10 inches) of
Clean the furnace with a dry or slightly moist cloth. Avoid using solvents. 2. Initial Start-Up and Installation
Keep the rear and side air vents completely unobstructed at all times.
High-quality quartz tube design providing uniform, multi-directional radiant heat. Key Components
Press the button. The furnace head will automatically descend according to the set closing time ( S ). V2cap V sub 2 (Vacuum Off): The temperature
The wire should just begin to melt at exactly 961.8°C.
The Programat P95 Manual is structured to guide you through every process, from initial installation to advanced troubleshooting. While the P95 is a robust furnace from the Programat legacy series, its operational philosophy aligns with other Ivoclar models, making its documentation universally applicable. The manual emphasizes the P95's core functions, which are designed to master the complexities of dental ceramics.
The core utility of the Ivoclar Programat P95 manual lies in its explanation of the user interface and programming capabilities. The Programat P95 is designed to handle a variety of materials, including Ivoclar’s renowned IPS e.max and classic metal-ceramics. The manual serves as a comprehensive guide to navigating the control panel, detailing how to select pre-set programs and how to customize firing cycles. For a dental technician, understanding the parameters of , heating rate , final temperature , and vacuum levels is essential. The manual decodes these variables, allowing the user to tailor the firing cycle to the specific thermal expansion coefficients of the ceramic material being used. Without the manual’s detailed charts and programming logic, a technician might inadvertently misuse the thermal cycle, leading to porous or cracked restorations.